Multifocal multiphoton microscopy (MMM) at a frame rate beyond 600 Hz

Published in:
Opt. Express, Vol. 15, No. 17, 20 August 2007, pp. 10998-11005.

Summary

We introduce a multiphoton microscope for high-speed three-dimensional (3D) fluorescence imaging. The system combines parallel illumination by a multifocal multiphoton microscope (MMM) with parallel detection via a segmented high-sensitivity charge-couple device (CCD) camera. The instrument consists of a Ti-sapphire laser illuminating a microlens array that projects 36 foci onto the focal plane. The foci are scanned using a resonance scanner and imaged with a custom-made CCD camera. The MMM increases the imaging speed by parallelizing the illumination; the CCD camera can operate at a frame rate of 1428 Hz while maintaining a low read noise of 11 electrons per pixel by dividing its chip into 16 independent segments for parallelized readout. We image fluorescent specimens at a frame rate of 640 Hz. The calcium wave of fluo3 labeled cardiac myocytes is measured by imaging the spontaneous contraction of the cells in a 0.625 second sequence movie, consisting of 400 single images.
READ LESS

Summary

We introduce a multiphoton microscope for high-speed three-dimensional (3D) fluorescence imaging. The system combines parallel illumination by a multifocal multiphoton microscope (MMM) with parallel detection via a segmented high-sensitivity charge-couple device (CCD) camera. The instrument consists of a Ti-sapphire laser illuminating a microlens array that projects 36 foci onto the...

READ MORE

LLiST - a new star tracker camera for tip-tilt correction at IOTA

Published in:
2004 SPIE Conf. on Astronomical Telescopes and Instrumentation, 21-26 June 2004.

Summary

The tip-tilt correction system at the Infrared Optical Telescope Array (IOTA) has been upgraded with a new star tracker camera. The camera features a backside-illuminated CCD chip offering doubled overall quantum efficiency and a four times higher system gain compared to the previous system. Tests carried out to characterize the new system showed a higher system gain with a lower read-out noise electron level. Shorter read-out cycle times now allow to compensate tip-tilt fluctuations so that their error imposed on visibility measurements becomes comparable to, and even smaller than, that of higher-order aberrations.
READ LESS

Summary

The tip-tilt correction system at the Infrared Optical Telescope Array (IOTA) has been upgraded with a new star tracker camera. The camera features a backside-illuminated CCD chip offering doubled overall quantum efficiency and a four times higher system gain compared to the previous system. Tests carried out to characterize the...

READ MORE